
16 Enabled Not Present
idrac System Disabled
Display the current flex address setting for slot 1.
racadm getflexaddr -i 1
Slot-1 server presence = Present
Slot-1 flexaddress enabled = 1
<
Fabric> <Type> <Server-Assigned> <Chassis-Assigned>
slot1-A1 Gigabit Ethernet 00:1C:
23:CD:AC:D2(active
)
00:1E:C9:FF:E3:21
iSCSI 00:1C:
23:CD:AC:D3(active
)
00:1E:C9:FF:E3:22
slot1-A2 Gigabit Ethernet 00:1C:
23:CD:AC:D4(active
)
00:1E:C9:FF:E3:23
iSCSI 00:1C:
23:CD:AC:D5(active
)
00:1E:C9:FF:E3:24
slot1-B1 Gigabit Ethernet 00:1D:09:71:B3:60 00:1E:C9:FF:E3:25(
active)
iSCSI 00:1D:09:71:B3:61 00:1E:C9:FF:E3:26(
active)
slot1-B2 Gigabit Ethernet 00:1D:09:71:B3:62 00:1E:C9:FF:E3:27(
active)
iSCSI 00:1D:09:71:B3:63 00:1E:C9:FF:E3:28(
active)
slot1-C1 Fiber Channel 4 10:00:00:00:C9:63:
51:0E
20:01:00:1E:C9:FF:
E3:29(active)
slot1-C2 Fiber Channel 4 10:00:00:00:C9:63:
51:0D
20:02:00:1E:C9:FF:
E3:29(active)
getfanreqinfo
Description Displays fan speed request for servers and switches in percent (%).
This subcommand is applicable only for CMC.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getfanreqinfo
Input None
Output None
56
Komentarze do niniejszej Instrukcji