
For CMC only:
• To configure the single property of a group:
racadm config -g cfgSerial -o cfgSerialBaudRate
• To modify a user password:
racadm config -g cfgUserAdmin -o cfgUserAdminPassword -i 3
newpassword
• To configure the single property of a group for a particular server:
racadm config -g cfgSessionManagement -o
cfgSsnMgtWebServerTimeout newvalue -m server-n
• To configure the remote Syslog property for a particular server:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m
server-n
• To configure the remote Syslog property for all servers:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogEnable 1 -m
server-all
• Configures the Enhanced Cooling Mode property for fans.
racadm config –g cfgThermal –o cfgThermalEnhancedCoolingMode 1
connect
Description Connects to the switch or server serial console.
This subcommand is applicable only for CMC.
Synopsis
• racadm connect [-b] <server-n>
• racadm connect [-b] <switch-n>
Input
-b Connects to the switch or console using the binary mode. -b is an optional; a server or a switch
must be present.
NOTE: If you use the -b option, reset the CMC to end the connect operation.
• server -nx —
where n=1–8; x = a,b,c,d
• switch -n — switch-n where n= <a1 | a2 | b1 | b2 | c1 | c2>
coredump
Description Displays detailed information related to any recent critical issues that have occurred with iDRAC.
The coredump information can be used to diagnose these critical issues.
If available, the coredump information is persistent across iDRAC power cycles and remains
available until either of the following conditions occur:
The coredump information is deleted with the coredumpdelete subcommand.
Another critical condition occurs on iDRAC. In this case, the coredump information is relative to the
last critical error that occurred.
This subcommand is applicable only for iDRAC.
NOTE: To use this subcommand, you must have the Execute Debug Commands permission.
34
Komentarze do niniejszej Instrukcji